07/28/2022

DV 06:28 PM PCB Development: RE: Termination resistors on RGMII signals?
Hello,
The MitySOM doesn't have physical series termination resistors for the RGMII signals but you can enable series termination within the Cyclone V SoC itself. The Cyclone V SoC supports either 25 Ohm or 50 Ohm series termination f...
Daniel Vincelette
 